rcbench
Servo and ESC test bench: panel, IOmcu and shared C
|
#include <supply_screen.h>
Data Fields | |
| bool | on |
| bool | off |
| bool | reset |
| bool | module_reset |
What the screen asks the application to do since the last poll. Both an OFF and a RESET PEAKS can be pending at once. An OFF outranks an ON: one that is pending drops any ON asked after it.
The set points are not in it. They are a level, read with supply_screen_set_v() and supply_screen_set_i(), so an application that loses a command does not lose the voltage the screen shows.
| bool supply_cmd_t::module_reset |
restart the PD mini
| bool supply_cmd_t::off |
switch it off
| bool supply_cmd_t::on |
switch the output on
| bool supply_cmd_t::reset |
start the extremes again